TítuloTwo-Phase Pressure Drop Correlation During the Convective Condensation in Microchannel Flows
Ano2018
Data de Acesso12 maio 2024
Tipo SecundárioPRE CI
Número de Arquivos1
Tamanho442 KiB
2. Contextualização
AutorRiehl, Roger Ribeiro
GrupoDIDMC-CGETE-INPE-MCTIC-GOV-BR
AfiliaçãoInstituto Nacional de Pesquisas Espaciais (INPE)
Endereço de e-Mail do Autorroger.riehl@inpe.br
Nome do EventoHeat Powered Cycles Conference
Localização do EventoGermany
Data16-19 sept.
Título do LivroProceedings
Histórico (UTC)2019-01-04 11:11:40 :: simone -> administrator ::
2021-02-11 18:14:26 :: administrator -> simone :: 2018
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-Chaveconvective condensation
microchannels
thermal control
pressure drop
ResumoThis paper presents the experimental results on two-phase pressure drop related to microchannel flows during convective condensation. Two pumping systems, one being on a capillary pumped loop (CPL) mode and the other being with a magnetic driven pump with variable flow rate, were used in the experimental apparatus to test microchannel condensers with methanol as the working fluid. Tests were conducted for two different saturation temperatures, for a range of heat dissipation rate from 20 to 350 W, four microchannel condensers and mass flow rates of up to 600 kg/m2 s. The results showed that the microchannel condensers presented high pressure drop (up to 63 kPa) for the mass flow rate applied, which is mainly related to the microchannels reduced geometry. The levels of pressure drop observed were also considered high, as only laminar flow was verified during the tests. A correlation for the two-phase multiplier was obtained to correlate the experimental data, which showed to predict 85 % of the experimental results within an error range of less than 35 % for both saturation temperatures tested. The obtained correlation presented very high sensibility when calculating the pressure drop along the microchannels, considering the geometric factors and heat transfer capabilities of such equipment, which was able to present a good correlation with the experimental data.
ÁreaETES
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDMC > Two-Phase Pressure Drop...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreement
agreement.html 04/01/2019 09:11 1.0 KiB 
4. Condições de acesso e uso
URL dos dadoshttp://urlib.net/ibi/8JMKD3MGP3W34R/3SG8K75
URL dos dados zipadoshttp://urlib.net/zip/8JMKD3MGP3W34R/3SG8K75
Idiomaen
Arquivo Alvoriehl_two.pdf
Grupo de Usuáriossimone
Visibilidadeshown
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/446AF4B
Acervo Hospedeirourlib.net/www/2017/11.22.19.04
6. Notas
Campos Vaziosarchivingpolicy archivist callnumber copyholder copyright creatorhistory descriptionlevel dissemination doi e-mailaddress edition editor format isbn issn label lineage mark mirrorrepository nextedition notes numberofvolumes orcid organization pages parameterlist parentrepositories previousedition previouslowerunit progress project publisher publisheraddress readergroup readpermission resumeid rightsholder schedulinginformation secondarydate secondarymark serieseditor session shorttitle sponsor subject tertiarymark tertiarytype type url volume
7. Controle da descrição
e-Mail (login)simone
atualizar 


Fechar